Add to Cart
Material | Oxidizing | Reducing or Neutral |
---|---|---|
SS 316L | 400℃(750℉) | 538℃(1000℉) |
SS 310S | 600℃(1100℉) | 816℃(1500℉) |
Inconel 600 | 600℃(1100℉) | 816℃(1500℉) |
Hastelloy X | 789℃(1450℉) | 926℃(1700℉) |
The filtering layer of Strengthened Hot Gas Cleaning Filters is made of a composite medium consisting of micrometer-level metal powder and multi-layered metal wire mesh.
The standard structure of Standard Hot Gas Cleaning Filters uses a core support layer of perforated porous tubes to meet the strength requirements. One end is closed and the other is open. A flange is welded at the open end to facilitate installation and fixation and ensure the sealing of high-temperature synthetic gas.
Model | Installation Diameter (mm) | Diameter D (mm) | Diameter d (mm) | Total Length L (mm) | Length l (mm) | Filter Area (m2) |
---|---|---|---|---|---|---|
HH-T-60-150 | 60 | 90 | 56 | 1500 | 1466 | 0.28 |
HH-T-60-175 | 60 | 90 | 56 | 1750 | 1716 | 0.33 |
HH-T-60-200 | 60 | 90 | 56 | 2000 | 1966 | 0.38 |
HH-T-60-225 | 60 | 90 | 56 | 2250 | 2216 | 0.42 |
HH-T-60-250 | 60 | 90 | 56 | 2500 | 2466 | 0.47 |
HH-T-60-300 | 60 | 90 | 56 | 3000 | 2966 | 0.57 |
Installation diameter refers to the diameter for filter installed on the installation plate. Other specifications are available upon request. |